Problems · AC leaking water

AC leaking water in Lake Mary, Florida

Condensate faults are the single most common AC service call in Florida. Most of the time water at the indoor unit is a clogged drain line or a tripped float switch doing exactly what it was built to do — stop the system before the overflow reaches a ceiling.

What is most likely wrong

  1. Clogged condensate drain line Very common

    Algae and biological growth clog the PVC line over a Florida summer; water backs up and overflows the pan.

  2. Full or clogged secondary drain pan Common

    Standing water visible in the secondary pan, or a stain on the ceiling below an attic air handler.

  3. Cracked or disconnected drain line Common

    A steady drip even with a clear line, usually where PVC sections meet.

  4. Frozen coil thawing Common

    A puddle appears once the ice on the coil melts after the system has been running hard — the leak is a symptom of a different fault. Frozen coil causes ›

  5. Improperly sloped drain line or missing trap Less common

    Slow drainage and recurring clogs even right after cleaning — an installation issue, not a maintenance one.

What you can safely check yourself

  • Where the water actually is: at the indoor air handler, or only at the outdoor condenser, which is often normal condensation and not a fault.
  • The condensate line where it exits the house: dripping steadily, dry, or backed up?
  • The float switch, if you can see it — if it has tripped, the system should be off, which means it is doing its job, not failing.
  • If the air handler is in the attic, check the ceiling below it for a fresh stain before assuming the drain is the whole story.

Refrigerant, capacitors and the inside of an electrical panel are not homeowner jobs — a run capacitor holds a lethal charge after the disconnect is pulled, and refrigerant handling requires EPA Section 608 certification under 40 CFR Part 82 subpart F.

In Florida, an air-conditioning contractor licensed under Chapter 489 may replace, disconnect and reconnect the power wiring at the dedicated disconnect — s. 489.105(3) — which is exactly why that scope exists: it is not general household electrical work. Verify any Florida air-conditioning contractor’s licence at myfloridalicense.com.

Why this shows up in Lake Mary and Heathrow

Condensate faults carry higher stakes in Lake Mary than in a slab-mounted system further north. In the 1988–1996 median-era stock and through Heathrow’s 1985–2019 build years, the air handler is routinely in the attic, so a clogged line does not just mean a puddle — it means a ceiling. Seminole County Property Appraiser CAMA extract (parcel file dated 5 September 2026), tax district M1 — City of Lake Mary — improved residential parcels only.

The system running almost year-round compounds it: near-continuous condensation means the drain line accumulates algae faster here than in a four-season climate, which is why a routine flush is one of the few maintenance items with a real payoff in this market.

What the fix typically costs

Researched Central Florida ranges — not our prices
ItemResearched rangeWhat drives it
Diagnostic / service call$79–$250Orlando third-party range; Central Florida contractors publish flat fees of $89–$95, usually credited toward the repair.
Condensate drain clearing$150–$250Orlando; the single most common Florida AC service call.

Researched Central Florida ranges gathered 12 September 2026 for research/pricing.json: Orlando-metro contractor-published prices corroborated against a third-party Orlando cost guide, with any aggregator figure labelled as such. These are market ranges, not our prices, and not a quote.