Problems · AC not turning on

AC not turning on in Lake Mary, Florida

When nothing responds at all — no fan, no compressor, no thermostat display — the fault is almost always electrical: power to the unit, or the low-voltage control circuit that tells it to start.

What is most likely wrong

  1. Tripped breaker Very common

    Nothing runs anywhere: no fan, no compressor, no display.

  2. Dead or miswired thermostat Very common

    Blank or unresponsive display; batteries if it takes them.

  3. Blown fuse or pulled disconnect at the condenser Common

    Indoor blower may run; outdoor unit is completely silent.

  4. Failed contactor Common

    A buzz or chatter at the outdoor disconnect, or nothing at all.

  5. Failed capacitor preventing a hard start Common

    A hum with no spin, then the unit trips off on overload.

  6. Failed control board or transformer Less common

    Thermostat is dead even with fresh batteries; usually needs a part ordered.

What you can safely check yourself

  • Both breakers; reset a tripped one once.
  • Thermostat batteries, and the screen for a blank or frozen display.
  • The outdoor disconnect pull-out, fully seated.
  • Whether the indoor blower runs at all when the thermostat calls for cooling — that narrows it to the outdoor side or the control side.

Refrigerant, capacitors and the inside of an electrical panel are not homeowner jobs — a run capacitor holds a lethal charge after the disconnect is pulled, and refrigerant handling requires EPA Section 608 certification under 40 CFR Part 82 subpart F.

In Florida, an air-conditioning contractor licensed under Chapter 489 may replace, disconnect and reconnect the power wiring at the dedicated disconnect — s. 489.105(3) — which is exactly why that scope exists: it is not general household electrical work. Verify any Florida air-conditioning contractor’s licence at myfloridalicense.com.

Why this shows up in Lake Mary and Heathrow

A completely dead system is one of the few AC faults where the local housing stock matters less than the electrical panel itself. The one Lake Mary-specific wrinkle: in Heathrow and the other 1985–2019 pockets, some homes run two or three separate systems, so a dead unit does not always mean a dead house — check whether the other zone or system is still running before assuming a whole-house outage.

Orlando runs roughly 3,452 cooling degree days a year on NOAA’s 1991–2020 normals, so a capacitor or contactor here accumulates start cycles faster than the same part in a four-season climate — which is why those two parts show up at both ends of this list, as a cause of no cooling and of no starting at all.

What the fix typically costs

Researched Central Florida ranges — not our prices
ItemResearched rangeWhat drives it
Contactor replacement$150–$350Orlando market range; Clear Comfort Orlando publishes $150–$250.
Capacitor replacement$150–$400Orlando market range. Clear Comfort Orlando, which lists Lake Mary in its service area, publishes $150–$300.
Control board replacement$400–$800Orlando; often requires a part to be ordered.
Thermostat replacement$180–$500Orlando market range; smart thermostats sit at the top.